UPS

》Key Specifications (10KVA 1:1) ▪︎Capacity: 10KVA (10000VA / 8000W). ▪︎Topology: True Online Double Conversion (Transformer-based with Inbuilt Galvanic Isolation). ▪︎Input/Output: Single Phase Input - Single Phase Output. ▪︎DC Voltage: 192 VDC (typically requires 16 x 12V batteries). ▪︎Input Voltage Range: Wide input range (e.g., 160V-300V AC or 110V-300V @ 50% load). ▪︎Power Factor: 0.99 Active Input PF / 0.8-0.9 Output PF. ▪︎Efficiency: Up to 92-94%. ▪︎Efficiency (Eco Mode): Up to 96%. 》Features ▪︎Galvanic Isolation: Inbuilt transformer for maximum protection, electrical isolation, and suppression of noise. ▪︎DSP Technology: Digital Signal Processor for higher reliability. ▪︎Bypass: Inbuilt Automatic and Manual (Maintenance) Bypass. ▪︎Generator Compatible: Suitable for power input from diesel generators. ▪︎Display: LCD / LED Display for monitoring voltage, load, and battery status. ▪︎Protection: Short-circuit, Overload, Over Temperature, Battery Low. ▪︎Communication: RS232, SNMP, USB (optional). 》Applications ▪︎Mid-sized server rooms and server racks. ▪︎Data centers and VoIP equipment. ▪︎Industrial, laboratory, and critical healthcare equipment.

6814772a5d263414004dd4a4 Card 2

product image
UPS

》Technical Specifications (10KVA 192V HF) ▪︎Capacity: 10000VA / 8000W (some models rated 7000W) ▪︎Topology: True Online Double Conversion with DSP Technology ▪︎Input (Phase: 1Ph-1Ph): ▪︎Voltage Range: 110~300VAC ± 3% (at 50% Load) to 176~300VAC ± 3% (at 100% Load) ▪︎Frequency Range: 46-54 Hz ▪︎Power Factor: > 0.99 @ 100% Load 》Output: ▪︎Voltage: 208/220/230/240 VAC ▪︎Voltage Regulation: ± 1% (Battery Mode) ▪︎Frequency Range: 46-54Hz (Line Mode), 50Hz ± 0.1% (Battery Mode) ▪︎Waveform: Pure Sine Wave ▪︎Power Factor: 0.8 (default), ▪︎Crest Factor: 3:1 (Max) ▪︎Transfer Time: Zero (AC to Battery Mode) 》Battery: ▪︎DC Voltage: Default 192VDC ▪︎Battery Configuration: 16 Nos (12V) batteries connected in series ▪︎Type: VRLA / SMF (External Battery Bank) ▪︎Charging Current: 4.0 A (Maximum) ▪︎Efficiency: AC Mode 94%, Battery Mode 91% 》Features: ▪︎LCD Display: I/P & O/P Voltage/Load Level/Battery Level ▪︎Automatic & Manual Bypass ▪︎RS-232 / SNMP for Communication ▪︎Generator Compatibility 》Environmental: ▪︎Operating Temp: 0-40 deg C ▪︎Noise: <60 dBA (1 meter)

6814772a5d263414004dd4a4 Card 2

product image
UPS

Technical Specifications Capacity: 6 KVA / 6000 VA Topology: True Online Double Conversion (High Frequency IGBT) Input Voltage Range: Wide input voltage range (e.g., 100-280VAC or 110-300VAC) Output Voltage: 220VAC / 230VAC / 240VAC ± 2% selectable Output Frequency: 50Hz ± 0.1Hz (Battery Mode) Waveform: Pure Sine Wave Power Factor: 1 (6kVA/6kW) DC Voltage: 192 VDC Battery System: External Battery Bank (requires 16x 12V batteries to make 192V) Key Features In-built Isolation Transformer: Available in specific models to protect against high voltage surges. Generator Compatible: Compatible with generator sets. Efficiency: High efficiency up to 94%. Display: LCD Display for monitoring UPS parameters. Protection: Over-current, Over-voltage, Short-circuit protection. Model Variations 6 KVA 192V: Often categorized as 16x12V battery configurations (16*12 = 192V). 6 KVA with Built-in Isolation Transformer: Specialized for industrial loads.

6814772a5d263414004dd4a4 Card 2

product image
UPS

Technical Specifications Capacity: 6 KVA / 6000 VA Topology: True Online Double Conversion (High Frequency IGBT) Input Voltage Range: Wide input voltage range (e.g., 100-280VAC or 110-300VAC) Output Voltage: 220VAC / 230VAC / 240VAC ± 2% selectable Output Frequency: 50Hz ± 0.1Hz (Battery Mode) Waveform: Pure Sine Wave Power Factor: 1 (6kVA/6kW) DC Voltage: 192 VDC Battery System: External Battery Bank (requires 16x 12V batteries to make 192V) Key Features Generator Compatible: Compatible with generator sets. Efficiency: High efficiency up to 94%. Display: LCD Display for monitoring UPS parameters. Protection: Over-current, Over-voltage, Short-circuit protection.

6814772a5d263414004dd4a4 Card 2

product image
UPS

》Technical Specifications: Champion 3 KVA Online UPS ▪︎Model : UPS-3KVA (HF / External Battery ▪︎Capacity : 3000 VA / 2400 Watts ▪︎Topology : True Online Double Conversion ▪︎Phase : Single Phase with Ground (1:1) 》Input Parameters ▪︎​Nominal Voltage: 220 VAC / 230 VAC ▪︎​Voltage Range: 115 VAC – 295 VAC ▪︎​Frequency Range: 46 Hz – 54 Hz (Auto-sensing) ▪︎​Power Factor: 97% 》​Output Parameters ▪︎​Output Voltage: 220 VAC / 230 VAC (+/- 2%) ▪︎​Frequency (Line Mode): Synchronized to mains (46 Hz – 54 Hz) ▪︎​Frequency (Battery Mode): 50 Hz \pm 0.1% ▪︎​Waveform: Pure Sine Wave ▪︎​Total Harmonic Distortion (THD): < 3% (Linear Load); < 5% (Non-linear Load) ▪︎​Crest Factor: 3:1 ▪︎​Transfer Time: 0 ms (Mains to Battery) ▪︎​Battery System (External) ▪︎​DC Bus Voltage: 96 VDC ▪︎​Battery Configuration: 8 Nos. x 12V batteries (connected in series) ▪︎​Charger Type: Constant Voltage & Constant Current (CVCC) ▪︎​Recharging Time: Typically 8 hours to 90% capacity (depends on battery AH) 》​Physical & Environmental ▪︎​Dimensions (W x D x H): 192 x 425 x 330 mm ▪︎​Net Weight: ~14 kg (excluding external batteries) ▪︎​Noise Level: < 60 dBA at 1 meter ▪︎​Operating Temp: 0°C to 40°C ▪︎​Humidity: 20% to 90% (Non-condensing) 》​Key Features ▪︎​DSP Technology: High-speed Microprocessor/DSP control for enhanced reliability. ▪︎​Cold Start: Ability to turn on the UPS using battery power without AC input. ▪︎​LCD Display: Real-time monitoring of Input/Output voltage, Load level, and Battery status. ▪︎​Communication: RS-232 port standard; SNMP slot available for remote web-based monitoring. ▪︎​Protection: Built-in protection against over-voltage, short circuits, and deep discharge.

6814772a5d263414004dd4a4 Card 2

product image
UPS

》Feature Specification ▪︎Capacity : 3000 VA / 2400 Watts (0.8 PF) ▪︎Topology : True Online Double Conversion (HF) ▪︎Input Phase : Single Phase with Ground (1:1) ▪︎Input Voltage Range :115V AC – 295V AC ▪︎Input Frequency : 46 Hz – 54 Hz ▪︎Output Voltage : 220V / 230V AC ± 2% ▪︎Output Waveform : Pure Sine Wave ▪︎Crest Factor : 3:1 ▪︎Efficiency : > 90% (Overall); > 92% (Inverter) 》Battery & Charging System ▪︎​DC Voltage: 96V DC. ▪︎​Internal Battery Configuration: 8 Nos. x 12V SMF (Sealed Lead Acid) batteries. ▪︎​Charging Type: Constant Voltage and Constant Current (CVCC). ▪︎​Recharging Time: Typically 8 hours to reach 90% capacity after a full discharge. ▪︎​Cold Start: Supported (can power up on battery mode without utility power). 》​Protections & Features ▪︎​Comprehensive Protection: Safeguards against input under/over voltage, output overload, short circuits, and battery low-voltage. ▪︎​Bypass: Built-in automatic bypass to ensure power continuity during internal faults. ▪︎​LCD Interface: Displays real-time status including Input/Output voltage, Load percentage, Battery level, and fault codes. ▪︎​Communication: Standard RS-232 port; optional SNMP slot for network-based remote monitoring. ​Physical & Environmental ▪︎​Dimensions (W x D x H): 192 x 425 x 330 mm. ▪︎​Net Weight: Approximately 28–32 kg (Weight is significantly higher than external models due to inbuilt batteries). ▪︎​Operating Temperature: 0°C to 40°C. ▪︎​Noise Level: < 50 dBA at 1 meter.

6814772a5d263414004dd4a4 Card 2

product image
UPS

》Feature Specification ▪︎Capacity : 1 KVA / 800 Watts (0.8 PF) ▪︎Topology : True Online Double Conversion ▪︎Input Phase : Single Phase with Ground (1:1) ▪︎Input Voltage Range : 115V AC – 295V AC ▪︎Input Frequency : 40 Hz – 70 Hz ▪︎Output Voltage : 220V / 230V / 240V AC ± 2% ▪︎Output Waveform : Pure Sine Wave ▪︎Transfer Time : Zero (AC to DC / DC to AC) ▪︎Crest Factor : 3:1 (Max) ▪︎Efficiency : > 90% (Overall) 》Battery & Charger System ▪︎​Nominal DC Voltage: 36V DC (Requires 3 x 12V batteries). ▪︎​Battery Type: External Battery Bank (supports high-capacity SMF or Tubular batteries for extended backup). ▪︎​Charging Current: Typically 9.5 Amps (High-speed charging for large external banks). ▪︎​Recharge Time: 8 hours to 90% capacity (depending on battery AH). 》​Key Features ▪︎​High Frequency (HF) Design: Compact footprint and lightweight compared to transformer-based models. ▪︎​LCD Display: Real-time monitoring of Input/Output voltage, Load level, Battery level, and Fault status. ​Cold Start: Ability to turn on the UPS directly from batteries without utility power. ▪︎​Protections: Built-in automatic bypass, short circuit protection, and over-temperature shutdown. ▪︎​Communication: RS-232 port standard; SNMP slot optional for remote network monitoring. 》​Physical Dimensions ▪︎​Size (W x D x H): 145 x 350 x 230 mm ▪︎​Net Weight: Approximately 6 kg (without batteries) ▪︎​Cooling: Forced Air (Internal Fan)

6814772a5d263414004dd4a4 Card 2

product image
UPS

》Technical Specifications ▪︎Capacity: 1000 VA / 800 Watts. ▪︎Input Voltage: 220 VAC, single phase with ground. ▪︎Input Voltage Range: 115 VAC – 295 VAC. ▪︎Output Voltage: 220/230 VAC ± 2%. ▪︎Output Waveform: Pure Sine Wave. ▪︎Frequency: 50 Hz; Synchronized 46–54 Hz (Line Mode) and 50 Hz ± 0.1% (Battery Mode). ▪︎Efficiency: > 90% overall; > 92% inverter efficiency. ▪︎Battery Type: Sealed Lead Acid (SMF). ▪︎Number of Batteries: Typically 3 internal batteries. ▪︎DC Voltage: 36 VDC. ▪︎Recharge Time: 8 hours to reach 90% capacity after a full load discharge. ▪︎Backup Time: 10–15 minutes (load dependent). 》Physical & Environmental ▪︎Dimensions: 145 x 350 x 230 mm. ▪︎Net Weight: 6 kg (without battery; total weight varies with inbuilt batteries). ▪︎Display: User-friendly LCD showing input/output voltage, load level, and battery status. ▪︎Operating Temp: 0–40°C with 20%–90% non-condensing humidity. ▪︎Audible Noise: Less than 60 dBA at 1 metre. 》Key Features ▪︎True Online Topology: Continuous double conversion for maximum reliability. ▪︎Protections: Safeguards against over-current, short circuits, over-voltage, and low battery. ▪︎Cold Start: Ability to start the UPS directly from batteries during a power outage.

6814772a5d263414004dd4a4 Card 2

product image
Inverter HKVA

》Technical Specifications ▪︎Capacity : 10000 VA (10 kVA) ▪︎Maximum : Load 8000 W ▪︎Voltage Support : 120V ▪︎Technology : Pure Sine Wave ▪︎Battery Support :10 Batteries (12V each) ▪︎Compatible Batteries : Flat, Tubular, and SMF (80Ah–250Ah) ▪︎Charging Current : User settable (8A–21A) ▪︎Dimensions : 55.5 x 30 x 60 cm ▪︎Net Weight : 80 kgs ▪︎Warranty : 3 Years 》Key Features ▪︎Intelligent LCD Display: Shows 8 to 14 real-time performance statistics, including backup time, charging time, running load status, and fault indications. ▪︎Flexible Performance Modes: Includes Eco Mode (140V–290V AC) for wider voltage range and UPS Mode (180V–265V AC) for sensitive appliances with changeover times under 20ms. ▪︎User Control: Allows setting output voltage between 200V and 240V to balance performance and backup time. ▪︎Safety Features: Equipped with a mains bypass switch and alarms for short circuits, overloads, over-temperature, and low battery.

6814772a5d263414004dd4a4 Card 2

product image
Inverter HKVA

》Technical Specifications ▪︎VA Rating : 7500 VA (7.5 kVA) ▪︎Max Bulb Load : 6000 W ▪︎Technology : Pure Sine Wave ▪︎System Voltage : 96V DC ▪︎No. of Batteries : 8 (12V each) ▪︎Max Charging Current : 21 Amp (User settable: 8A–21A) ▪︎Output Voltage : User settable (200V–240V) ▪︎Change Over Time : < 20ms (in UPS and ECO modes) ▪︎Dimensions (cm) : 55.5 x 30 x 60 ▪︎Net Weight : 65 kg ▪︎Warranty : 3 Years 》Key Performance Features ▪︎Intelligent LCD Display: Provides real-time statistics, including backup time, charging time, running load percentage, and fault alerts. ▪︎Dual Modes: °UPS Mode: Keeps output voltage between 180V–265V, ideal for sensitive appliances like computers. °Eco Mode: Widens the voltage range to 140V–290V to reduce battery usage when grid power is stable. ▪︎Advanced Protection: Includes a mains bypass switch for continued power during inverter faults and MCB protection against short circuits, overloads, and overheating. Battery Compatibility: Supports Flat Plate, Tubular, and SMF (Sealed Maintenance Free) batteries with capacities ranging from 80Ah to 250Ah.

6814772a5d263414004dd4a4 Card 2

product image
Inverter HKVA

The Luminous Optimus 6500+ is a high-capacity (HKVA) pure sine wave inverter designed for heavy loads in large residences, offices, or commercial spaces. 》Technical Specifications Overview ▪︎VA Rating: 5500 VA (5.5 KVA) ▪︎Maximum Peak Load: 4400 W (bulb load capacity often cited as 3800 W) ▪︎Battery System: 72V DC (Requires 6 batteries of 12V each) ▪︎Output Voltage: User-settable between 200V – 240V to balance backup time vs. performance ▪︎Technology: Microcontroller-based Pure Sine Wave for safe operation of sensitive electronics. 》Detailed Data Sheet ▪︎Charging Current : User-settable between 8A – 21A for optimized battery life ▪︎Battery Compatibility : Supports Flat, Tubular, and SMF batteries (80Ah – 250Ah) ▪︎Operating Modes : Eco Mode (85V – 290V) and UPS Mode (180V – 265V) ▪︎Change Over Time : <20ms (UPS mode) ▪︎Safety Protections : Short circuit, Overload, Over temperature, Low battery, and Mains MCB protection ▪︎Display LCD showing real-time stats: backup time, charging time, load %, and fault alerts ▪︎Physical Dimensions : 30 x 47.1 x 45.2 cm ▪︎Net Weight Approx. : 31.5 kg ▪︎Warranty : 3Years 》Key Features ▪︎Fast Charging: Begins at low input voltage (95V) and offers fast charging from 135V. ▪︎Mains Bypass Switch: Allows the grid power to pass directly to the load in case of an internal inverter fault. ▪︎Load Capability: Can power heavy appliances like 1.5-ton air conditioners, refrigerators, and multiple office computers.

6814772a5d263414004dd4a4 Card 2

product image
Inverter HKVA

》Technical Specifications ▪︎VA Rating : 5000 VA (5 KVA) ▪︎Rated Power : (Wattage) 4000 W ▪︎System Voltage : 48V (Requires four 12V batteries) ▪︎Technology : Pure Sine Wave ▪︎Charging Current : User settable between 8A – 21A ▪︎Output Voltage : User selectable between 200V – 240V ▪︎Input Voltage (Charging) : Low voltage starts at 95V; Fast charging from 135V ▪︎Changeover Time : < 20 ms in both UPS and ECO modes ▪︎Dimensions (cm) : 30 x 36.7 x 42.9 ▪︎Net Weight : 36 kg 》Key Features ▪︎Informative LCD Display: Shows 8 real-time performance statistics, including remaining backup time, charging time, load percentage, and fault alerts. ▪︎Dual Operating Modes: °UPS Mode: Keeps output voltage between 180V–265V, ideal for sensitive electronics like computers. °Eco Mode: Operates in a wider voltage range (140V–290V) to reduce battery usage when the grid is stable. ▪︎Battery Compatibility: Supports all battery types, including Flat Plate, Tubular, and SMF (VRLA), with capacities ranging from 80Ah to 250Ah. ▪︎Safety Protections: Features built-in protection against short circuits, overloads, over-temperature, and deep discharge. ▪︎Mains Bypass Switch: Allows for direct grid supply to the load in the event of an inverter fault. ▪︎Warranty : 3 Years