Vadodara
08048034714
+919898384455
UPS

Champion Online UPS 1 KVA (1:1) 36V HF External Battery

Phone Number

08048034714

Please keep 0 before dialling the number.

Mon-Thu: 10 AM - 2 PM • Fri: 3 PM - 7AM

Other Website Visit our other website
Address 10/111, Brij Industries, Opp. Marutidham, GIDC Main Road, Makarpura, Vadodara.

Vadodara, India, 390010

Description

》Feature Specification ▪︎Capacity : 1 KVA / 800 Watts (0.8 PF) ▪︎Topology : True Online Double Conversion ▪︎Input Phase : Single Phase with Ground (1:1) ▪︎Input Voltage Range : 115V AC – 295V AC ▪︎Input Frequency : 40 Hz – 70 Hz ▪︎Output Voltage : 220V / 230V / 240V AC ± 2% ▪︎Output Waveform : Pure Sine Wave ▪︎Transfer Time : Zero (AC to DC / DC to AC) ▪︎Crest Factor : 3:1 (Max) ▪︎Efficiency : > 90% (Overall) 》Battery & Charger System ▪︎​Nominal DC Voltage: 36V DC (Requires 3 x 12V batteries). ▪︎​Battery Type: External Battery Bank (supports high-capacity SMF or Tubular batteries for extended backup). ▪︎​Charging Current: Typically 9.5 Amps (High-speed charging for large external banks). ▪︎​Recharge Time: 8 hours to 90% capacity (depending on battery AH). 》​Key Features ▪︎​High Frequency (HF) Design: Compact footprint and lightweight compared to transformer-based models. ▪︎​LCD Display: Real-time monitoring of Input/Output voltage, Load level, Battery level, and Fault status. ​Cold Start: Ability to turn on the UPS directly from batteries without utility power. ▪︎​Protections: Built-in automatic bypass, short circuit protection, and over-temperature shutdown. ▪︎​Communication: RS-232 port standard; SNMP slot optional for remote network monitoring. 》​Physical Dimensions ▪︎​Size (W x D x H): 145 x 350 x 230 mm ▪︎​Net Weight: Approximately 6 kg (without batteries) ▪︎​Cooling: Forced Air (Internal Fan)

Other Products

view all

6814772a5d263414004dd4a4 Card 2

product image
Servo Stabilizer

PARAMETER Brand : Krykard •3 PHASE UNBALANCED OIL COOLED •Rating (kVA) : 100kVA - 4000 kVA •Type of Cooling : Oil •Input Voltage Range : (V L-L)* 310 V - 480 V / 340 V - 480 V / 360 V - 460 V / 360 V - 480 V •Output Voltage Range : (V L-L)* 415 V (380 V / 400 V - optional) •Output Voltage Regulation : 1% of nominal output voltage •Input Frequency Range : 47 Hz - 53 Hz •Efficiency: > 98% •Effect of Load Power Factor : Nil •Waveform Distortion : Nil •Type of Servo : Control Micro Controller based True RMS sensing and correction •Servo Motor Drive : Triac based drive for AC step synchronous motor •Under / Over Voltage Cutoff : * Electronic cutoff circuit with graded time delay, set @ +5% / -10% of nominal output voltage •Overload Cutoff : CT based electronic cutoff circuit with graded time delay set @ 110% of rated full load current •Short Circuit Protection : MCB / MCCB provided up to 100 kVA; HRC fuse provided for 125 - 175 kVA; Optional >200 kVA •Single Phasing Prevention : Provided in AU / OU models only; Not provided in the AR / OR models Phase Reversal Trip Provided in AU / OU models only; Not provided in the AR / OR models. •Stabiliser Bypass : Provided up to 50 kVA 3 - phase; Optional > 50 kVA •Transient Supression : Spike suppression through MOV is provided (Surge Arrestor is optional) Emergency Off Switch Provided in AU / OU models only; Not provided in the AR / OR models Frequency Cutoff Protection Optional •Input High Voltage Trip Optional •Resetting Mode : Manual / Auto option provided with programmable time delay •Display Type : 2 line LCD panel •Parameters Displayed : Input & Output Voltages (Line & Phase), Output Currents & Frequency •Input / Output Terminations : Bolted terminals up to 100 kVA, Busbar 125 kVA & above •Standards : IS 9815 ( Part -1); 1994

6814772a5d263414004dd4a4 Card 2

product image
Servo Stabilizer

PARAMETER • Brand : Krykard •3 PHASE UNBALANCED AIR COOLED •Rating (kVA) : 3 kVA - 150 kVA •Type of Cooling : Air •Input Voltage Range : (V L-L)* 310 V - 480 V / 340 V - 480 V / 360 V - 460 V / 360 V - 480 V •Output Voltage Range : (V L-L)* 415 V (380 V / 400 V - optional) •Output Voltage Regulation : 1% of nominal output voltage •Input Frequency Range : 47 Hz - 53 Hz •Efficiency: > 98% •Effect of Load Power Factor : Nil •Waveform Distortion : Nil •Type of Servo : Control Micro Controller based True RMS sensing and correction •Servo Motor Drive : Triac based drive for AC step synchronous motor •Under / Over Voltage Cutoff : * Electronic cutoff circuit with graded time delay, set @ +5% / -10% of nominal output voltage •Overload Cutoff : CT based electronic cutoff circuit with graded time delay set @ 110% of rated full load current •Short Circuit Protection : MCB / MCCB provided up to 100 kVA; HRC fuse provided for 125 - 175 kVA; Optional >200 kVA •Single Phasing Prevention : Provided in AU / OU models only; Not provided in the AR / OR models Phase Reversal Trip Provided in AU / OU models only; Not provided in the AR / OR models. •Stabiliser Bypass : Provided up to 50 kVA 3 - phase; Optional > 50 kVA •Transient Supression : Spike suppression through MOV is provided (Surge Arrestor is optional) Emergency Off Switch Provided in AU / OU models only; Not provided in the AR / OR models Frequency Cutoff Protection Optional •Input High Voltage Trip Optional •Resetting Mode : Manual / Auto option provided with programmable time delay •Display Type : 2 line LCD panel •Parameters Displayed : Input & Output Voltages (Line & Phase), Output Currents & Frequency •Input / Output Terminations : Bolted terminals up to 100 kVA, Busbar 125 kVA & above •Standards : IS 9815 ( Part -1); 1994

6814772a5d263414004dd4a4 Card 2

product image
Servo Stabilizer

Specification • Brand : Krykard - 1 PHASE • Rating (kVA) : 1 kVA, 2 kVA, 3 kVA, 4 kVA, 5 kVA, 7.5 kVA, 10 kVA, 15 kVA and 20 kVA • Input Voltage Range: 190 V - 250 V and 170 V - 270 V • Output Voltage Range 220 V + 1% • Input Frequency Range 47 - 53 Hz • Digital Display 3 digit, 7 segment display • Accuracy of Voltage 1% + 1 digit • Under Voltage / Over Voltage Trip (Default) +5% and -10% of Output Set Voltage • Short Circuit Protection MCB • Transient Protection Spike suppressor (MOV) provided Product range appropriate for your need • Regular Range: 190 - 250V - for factories, offices & urban locations • Wide Range: 170 - 270V - for semi-urban locations with wide fluctuations 》True RMS Correction • Microprocessor based control system for measurement and correction • Digital Voltage, Current display through high visibility LED 》Reliable by Design • Stabilisers designed to its rated capacity • Lowest failure rates and life cycle cost in the Industry. • 1 year 'No-Questions-Asked guarantee 》Complete Protection • Short Circuit. • Under voltage Over voltage • Electronic CT based Overload trip • Built-in Spike Suppressor 》Dependable After Sales Support • Wide service network covering 100 + locations across India. • Committed Service response ◇within 6 hours in service towns and ◇ within 24 hours in the same State